The following text field will produce suggestions that follow it as you type.

2015-06-30 Energy Conservation Program - Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps - Final rule (US Energy Efficiency and Renewable Energy Office Regulation) (EERE) (2018 Edition)
2015-06-30 Energy Conservation Program - Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps - Final rule (US Energy Efficiency and Renewable Energy Office Regulation) (EERE) (2018 Edition)

2015-06-30 Energy Conservation Program - Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps - Final rule (US Energy Efficiency and Renewable Energy Office Regulation) (EERE) (2018 Edition)

Current price: $19.90
Loading Inventory...
Get it at Barnes and Noble

Size: OS

Get it at Barnes and Noble
2015-06-30 Energy Conservation Program - Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps - Final rule (US Energy Efficiency and Renewable Energy Office Regulation) (EERE) (2018 Edition) The Law Library presents the complete text of the 2015-06-30 Energy Conservation Program - Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps - Final rule (US Energy Efficiency and Renewable Energy Office Regulation) (EERE) (2018 Edition). Updated as of May 29, 2018 On March 13, 2014, the U.S. Department of Energy (DOE) issued a notice of proposed rulemaking (NOPR) to amend the test procedures for packaged terminal air conditioners (PTACs) and packaged terminal heat pumps (PTHPs). That NOPR serves as the basis for this final rule regarding the test method for PTACs and PTHPs. The amendments adopted here do not affect measured energy use. These changes incorporate by reference certain sections of the latest versions of industry test procedures AHRI Standard 310/380-2014, ANSI/ASHRAE Standard 16-1983 (RA 2014), ANSI/ASHRAE Standard 37-2009, and ANSI/ASHRAE Standard 58-1986 (RA 2014), and specify additional testing provisions that must be followed including an optional break-in period, require that cooling capacity tests be conducted using electricity measuring instruments accurate to +/− 0.5% of reading, explicitly require that wall sleeves be sealed, allow for the pre-filling of the condensate drain pan, and require testing with 14-inch deep wall sleeves and the filter option most representative of a typical installation. This book contains: - The complete text of the 2015-06-30 Energy Conservation Program - Test Procedures for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps - Final rule (US Energy Efficiency and Renewable Energy Office Regulation) (EERE) (2018 Edition) - A table of contents with the page number of each section
Powered by Adeptmind